| Restocking Fee | No |
|---|---|
| Return shipping will be paid by | Buyer |
| All returns accepted | Returns Accepted |
| Item must be returned within | 30 Days |
| Refund will be given as | Money back or replacement (buyer's choice) |
| Brand | Measurement Solutions |
| Custom Bundle | No |
| Model | MSLSC |
| MPN | MSLSC-RC-05V-WP |
| Country/Region of Manufacture | United States |
| Modified Item | No |
Check the listing for details. 0-5 VDC Signal Conditioner for Load Cell or other Wheatstone Bridge sensor. Condition: New. Listed at 350.00 USD. Signal Conditioner accepts +/- mV/V Input and provides an Analog Output of 0-5 VDC.Requires a power supply: Anything from 8-30 VDC. High accuracy precision differential amplifierDesigned for use in harsh environmentsLow thermal error, operate from -40 to +125 CFast Response Time: 1 mS (1000 Hz)?Gland Nut? connections for in and out cablesScrew terminals, internal (for wire terminations)Course & Fine Zero & Span AdjustmentsActivate R-CAL (Shunt Cal) with internal switch. Specifications:Power Supply: 8-30 VDC @ 90 mA maxInput: +/-1.5 to +/-4.5 mV/V (bi-polar)Output: 0-5 VDC (uni-polar)Bridge Excitation: 5 VDC maxBridge Resistance: 300 - 1000 OhmsNon-linearity: ±0.005% FSTemperature drift: 35 ppm/?Long term stability: ±0.08% FS/yearOutput Noise: ±2 mV maxOver voltage protection: ?40 VDCReverse polarity protection: ?40 VDC