| Restocking Fee | No |
|---|---|
| Return shipping will be paid by | Buyer |
| All returns accepted | Returns Accepted |
| Item must be returned within | 60 Days |
| Refund will be given as | Money Back |
| Country/Region of Manufacture | China |
| Inside capacity | 14/ 18 Liter |
| Material | Stainless steel #304 |
| Type | 14/18L Autoclave (Steam Sterilizer) |
| Sterilize time | 25min & 6min |
| MPN | MJ1020100931 |
| Brand | Unbranded |
| Sterilizer Type | Autoclave (Steam Sterilizer) |
| Intended Use/Discipline | Dental Laboratory |
Check the listing for details. 14L/18L Dental Autoclave Steam Sterilizer Medical Sterilization Lab Equipment. Condition: New. Listed at 469.20 USD. Description: Steam Sterilizer TR250NM-1 Description:Chamber capacity:Ø25×D35CM (Ø9.84×D13.78inch)Inside capacity:18 LiterMaterial:Stainless steel #304Outside Size(L*W*H) :56*39*36 CMPacking Size(L*W*H) :64*46*41 CMG.W:25.5KGSSterilizer temperature/pressure:121℃/0.12Mpa; 134℃/0.22MpaSterilize time:25Min/6MinPower:900WAC110V/8AAC220V/4AAuto supply water system: Manual give the waterSAFETY : Heating-over protection ; safety valveSafety equipment:1.Pressure adjustment: adjust the inter pressure, if over standard valueautomatic vent2. Avoild overheat protect device: when inter temperature overheat, power break electric current automatically.Temp and Press display :Led several windowsDisinfection principle:Uses the vapor power emissions cold air / 2 timesCaution:1.After the completion of disinfection,please to wait for 10 minutes.Pressure Gauge in red area. Do not rotate handle, open the steam discharge valve firstly.2.Before each use,must supply water 800ml of distilled water .3.Please close steam discharge valve before the disinfection.4.Do not use any corrosive or chemical water as the disinfection.5.Do not share the same electricoutllet with other electrical apparetus.6.Please pay attention to correct voltage and frequency.7.Connect steam exhaust pipe with the steam vent,before operation.Packing:main unit 1pcStandard accessories:Plate 3pcsShelf 1pcTake Plate tool 1pcsteam exhaust pipe 1pc ------------------------------------------------------------------------------------------------------------------ Steam Sterilizer With Drying function TR250C: Description:Voltage:110V /220V, 50Hz/60HzHeater Power: 1100WTank capacity: 18LInside dimensions: Φ250 x D350mm Sterilize temperature: 122℃ & 134℃Sterilize pressure: 0.12Mpa & 0.23Mpa Sterilize time: 25min & 6min Drying time: 40min Tank Material: Stainless steel #304 Machine size (L*W*H): 60 * 39 * 36cmPacking size (L*W*H): 61 * 53 * 40cmN.W.: 33KGG.W.: 35KG Standard accessories: (Plate * 3PCS; Shelf * 1PCS; Plate Taking tool * 1PC)Application: For dental, surgery, beauty salon, medical care, laboratory, and so on. Caution:1.After the completion of disinfection,please to wait for 10 minutes.Pressure Gauge in red area. Do not rotate handle, open the steam discharge valve firstly.2.Before each use,must supply water 800ml of distilled water .3.Please close steam discharge valve before the disinfection.4.Do not use any corrosive or chemical water as the disinfection.5.Do not share the same electricoutllet with other electrical apparetus.6.Please pay attention to correct voltage and frequency. 7.Connect steam exhaust pipe with the steam vent,before operation. --------------------------------------------------------------------------------------------------- Dental Autoclave Steam Sterilizer Medical sterilization lab equipment 14LDescription:Chamber capacity:Ø25×D28CM (Ø9.84×D11.02inch)Inside capacity:14 LiterMaterial:Stainless steel #304Outside Size :46.5*35*36 CMPacking Size :51*39*40 CMG.W:15KGSSterilizer temperature:121℃Sterilize pressure:0.12MpaSterilize time:25MinPower:900WAC110V/8AAC220V/4AAuto supply water system: Manual give the waterSafety valve: automatic discharge in excess of standard valueTemp and Press display:Pressure gaugeDisinfection principle:Uses the vapor power emissions cold air / 2 timesOperation Steps:1.Plug in the power cord2.Shut exhaust needle valve in the Close (clockwise)°3.Adding about 800 ml of distilled water. Close the door cover, tight the rotate handle4. Start the timer knob to 121 ℃ position. Sterilization is working.5.Sterilization is complete, please be sure to open the exhaust needle valve firstly (inverse clock direction)6.Wait for the pressure gauge pointer to zero, opened the door coverCaution:Every time sterilization, must add about 800 ml of distilled waterUse a separate socket (confirm the socket of the output voltage)Pressure gauge pointer in the red areas, please be sure to first Open the exhaust steam of the needle valvePacking:main unit 1pcStandard accessories:Plate 3pcs ( Size:201*136*21 mm)Shelf 1pcTake Plate tool 1pc steam exhaust pipe 1pc(1 meter length) FDA Statement The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. Seller name: dentex2019 City,State: SHENZHEN,China Telephone number: 0755-26789362 Payment We only accept paypal payment,it is easy and safe. and for any other payment forms,please kindly contact us in advance. Shipping The goods you ordered will be posted out in the second working day after the payment has been made. (We will inform you via email if any delay occurred due to holiday events. General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal) About Us If you have any query or dissatisfaction, please find our customer service via eBay Message Center only. If you send message via eBay message, we'll reply you within 24 working hours. Thank you so much for your purchase. Wish you have a nice day! : -)