| Restocking Fee | No |
|---|---|
| Return shipping will be paid by | Buyer |
| All returns accepted | Returns Accepted |
| Item must be returned within | 30 Days |
| Refund will be given as | Money back or replacement (buyer's choice) |
| Frequency Range | Range Auto, Manual |
| Trigger Mode | INT/BUS/EXIT |
| Custom Bundle | No |
| Measurement Functions | Multimeter |
| Product | Multimeter |
| MPN | 2022 |
| Modified Item | No |
| California Prop 65 Warning | Multimeter |
| Brand | VTSYIQI |
| Form Factor | Multimeter |
| Output Impedance | Multimeter |
| Model | Multimeter |
| Country/Region of Manufacture | China |
| Test Parameter | DCV, ACV, DCI, ACI, DCR, CP, FREQ, CONT, DIODE, TEMP |
| Display | High brightness VFD dual-display |
Check the listing for details. Digit Multimeter 120000 Count Display High Brightness VFD Dual-Display. Condition: New. Listed at 1034.90 USD. Digit Multimeter 120000 Count Display High Brightness VFD Dual-DisplayFeatures■ 120000 count display■ High brightness VFD dual-display■ True-rms AC voltage and current test■ Multiple mathematics operation function DCV/ACV/DCI/ACI/AC+DC/Ω/ CAP/ Temperature/ Frequency/ Diode/Continuity and dB/dBm■ Other parameters in current test signal displayed in second display■ Max. ADC sampling rate can be 200 times/s■ DCV test accuracy up to 0.012%,resolution up to1μV■ Relative mode(REL)to eliminate remaining reading■ Calibration without opening the case■ Limit function(Limit), for fast sorting■ Data statistics function Max/Min, Max. value, Min. value, Average value and number of statistics■ Standard USB interface,provide convenient system communication function ■ Standard Handler interface,provide external trigger and sorting signal for production line TH1952 5 1/2 digit multimeter is a multi-functional, costeffective voltage /current /resistance /capacitance meter. It provides Max. 120000 count, Max. sampling rate 200 times/s, 0.012% DCV accuracy,etc, which is the optimal selection for users.TH1952 provides high brightness VFD Dual-display, which can display ACV/DCV or DCI, ACV/ACI and frequency .etc to improve the test efficiency and, clearer display.TH1952 is configured with USB interface, and also communication software is provided for PC communication, data analysis, statistics, building system. TH1952 accepts SCPI command to be compatible with communication software. Also Handler interface is provided to receive the external trigger and output sorting signal for production line. SpecificationsTest FunctionTest ParameterDCV, ACV, DCI, ACI, DCR, CP, FREQ, CONT, DIODE, TEMPMathematics Function%, dB, dBm, REL, mX+bRangeAuto, ManualDisplayHigh brightness VFD dual-displayTrigger ModeINT/BUS/EXITReading HoldTo find out best stable reading for each data block of the given reading number according to the given accuracy.LimitationMeasurementTo judge HI、IN、LO and display, with ALARM for HI/LOCalibrationAuto, ManualExternal TriggerHandle interface (external trigger and output sorting signal)Communication InterfaceSCPI command support for RS232 and USB interfacePerformance parameter expression of uncertainty: ±(% of reading+% of full scale)Reading Rate(reading/s)Reading RateFastSlow1/21/21/21/2DCV/DCI8015154ACV/ACI8015154Ω8015154DCVRangeMin. ResolutionMax. Uncertainty(1 year)100mV-1000V1µV0.012%+0.008%DCIRangeMin. ResolutionMax. Uncertainty(1 year)1mA-100mA10nA0.05%+0.005%1A10µA0.10%+0.008%10A100µA0.20%+0.006%ACVRangeFrequencyMin. ResolutionMax. Uncertainty(1 year)100mV-750V20Hz-50Hz1µV1.00%+0.1%50Hz-10kHz0.20%+0.08%10kHz-30kHz0.80%+0.08%30kHz-100kHz3.00%+0.2%ACIRangeFrequencyMin. ResolutionMax. Uncertainty(1year)1mA -10A20Hz-50Hz10nA1.0%+0.08%50Hz-2kHz0.5%+0.08%2kHz-10kHz2.0%+0.18%ResistanceRangeMin. ResolutionMax. Uncertainty(1 year)100Ω-1MΩ10µΩ0.05%+0.008%10MΩ100Ω0.20%+0.008%100MΩ1kΩ2.00%+0.005%CapacitanceRangeMin. ResolutionMax. Uncertainty(1 year)1nF1pF2%+0.8%10nF-1000uF10pF1.0%+0.5%10000uF1uF2%+0.5%FrequencyRangeVoltage sensitivityMin. ResolutionMax. Uncertainty(1year)1Hz-1MHz40mV rms10µHz0.005%+0.003%TemperatureRangeProbe typeMin. ResolutionMax. Uncertainty(1year)-10℃-100℃PT5000.1℃Probe accuracy±0.2℃Uncertainty is not assured if the temperature is out of the range