| Restocking Fee | No |
|---|---|
| Return shipping will be paid by | Buyer |
| All returns accepted | Returns Accepted |
| Item must be returned within | 14 Days |
| Refund will be given as | Money Back |
| Modified Item | No |
| Country/Region of Manufacture | Japan |
| MPN | 3390-10 |
| Brand | Hioki |
Check the listing for details. Hioki 3390-10 3-Phase 4-Wire High Precision Power -Case Included. Condition: Used. Listed at 6350.00 USD. Hioki 3390-10 3-Phase 4-Wire High Precision Power Analyzer (0.5Hz to 150kHz DC)Included:Hioki CT6863-10, 200A, SN:190102352Hioki CT6863-10, 200A, SN:161212057Inno Disk CFC-ADP04Power CordTest CablesHioki Carrying CaseExcellent working Condition! The only defect that was the right side handle had a small crack- it was repaired- see photo. Enhanced accuracy parameters available with the higher accuracy combination:Voltage Measurement Accuracy: DC (45 to 66 Hz accuracy remains the same as the 3390)Current and Active Power Measurement Accuracy: DC and 45 to 66HzEffect of Power Factor: 45 to 66HzManufacturer SpecsSpecification Hioki 3390-10Accuracy Voltage (U)Current (I)Active Power (P)DC±0.07%rdg.±0.1%f.s.±0.07%rdg.±0.1%f.s±0.07%rdg.±0.1%f.s.45Hz to 66Hz±0.05%rdg.±0.05%f.s.±0.05%rdg.±0.05%f.s.±0.05%rdg.±0.05%f.s.Accuracy is defined for the frequency range indicated above only when pairing Model 3390-10 with HIOKI high accuracy current sensors (where f.s. is based on the ranges of the 3390-10).Voltage and active power values for 1000V or higher measurements are for reference only. Voltage (U)Current (I)Active Power (P)0.5Hz to 30Hz±0.1%rdg.±0.2%f.s.±0.1%rdg.±0.2%f.s.±0.1%rdg.±0.2%f.s.30Hz to 45Hz±0.1%rdg.±0.1%f.s.±0.1%rdg.±0.1%f.s.±0.1%rdg.±0.1%f.s.66Hz to 1kHz±0.1%rdg.±0.1%f.s.±0.1%rdg.±0.1%f.s.±0.1%rdg.±0.1%f.s.1kHz to 10kHz±0.2%rdg.±0.1%f.s.±0.2%rdg.±0.1%f.s.±0.2%rdg.±0.1%f.s.10kHz to 50kHz±0.3%rdg.±0.2%f.s.±0.3%rdg.±0.2%f.s.±0.4%rdg.±0.3%f.s.50kHz to 100kHz±1.0%rdg.±0.3%f.s.±1.0%rdg.±0.3%f.s.±1.5%rdg.±0.5%f.s.100kHz to 150kHz±20%f.s.±20%f.s.±20%f.s.For current and active power accuracy within the frequency range indicated above, add the uncertainty range of the current sensors.Current InputCurrent InputOnly when using HIOKI high-accuracy current sensors (options) (Accuracy specifications defined for Model 3390 apply when other sensors are used)Temp./Humidity Range23°C±3°C(73°F±5°F), max. 80% rh (3390-10)23°C±5°C(73°F±9°F), max. 80% rh (when using the 50A to 500A range of Model 9709-10)±1°C(1.8°F) of temperature after zero adjustment, within 23°C±5°C(73°F±9°F), max. 80% rh (when using the 10A and 20A range of Model 9709-10)0 to 40°C(32°F to 104°F), max. 80% rh (when using Model CT6862-10 or CT6863-10)Warm-up timeAt least 30 minutesInputOn condition that the signal is a sine wave, with power factor=1, voltage to ground=0V, after zeroadjustment is conducted with current sensors at 23°C±3°C(73°F±5°F), and when the fundamental waveform is the sync sourceTemperature CoefficientWhen used within the operating temperature range but outside the guaranteed temperature and humidity ranges for accuracy, add the following (the f.s. of the ranges of Model 3390-10 applies)3390-10±0.01%f.s./°C; for DC, add ±0.01%f.s./°C