| Return shipping will be paid by | Buyer |
|---|---|
| All returns accepted | Returns Accepted |
| Item must be returned within | 14 Days |
| Refund will be given as | Money Back |
Check the listing for details. HIOKI / 히오키 PQ3100-92 POWER QUALITY ANALYZER/ 전원 품질 분석기. Condition: Used. Listed at 7298.00 USD. PRODUCT NAME: HIOKI PQ3100-92 The unit is in MINT condition, almost new...comes with bag & accessories (Kindly see attached photos) We currently have 2 units in stock. Manufacturer SpecsMeasurement line typeSingle-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel CH4 for voltage/current, (all channels AC/DC measurement)Voltage rangesVoltage measurement: 1000.0 V rms or DC, Transient measurement 2.200 kV peakCurrent ranges50.000 mA AC to 5.0000 kA AC, 10.000 A DC to 2.0000 kA DC(depends on current sensor in use)Power ranges50.000 W to 6.0000 MW (determined automatically based on current range in use)Basic accuracyVoltage: ±0.2% of nominal voltage, Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy, Active power: DC ±0.5 % rdg. ±0.5 % f.s. + current sensor accuracy, AC ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracyMeasurement items1. Transient over voltage : 200 kHz sampling2. Frequency cycle : Calculated as one cycle3. Voltage (1/2) RMS, Current (1/2) RMS: one cycle calculation refreshed every half cycle4. Voltage swell, Voltage dips, Voltage interruption, RVC(Available in future firmware update) : Voltage (1/2) RMS calculation5. Inrush current : half-cycle calculation: Calculated as the current RMS value for current waveform data sampled every half-cycle.6. Frequency 200 ms: Calculated as 10 or 12 cycles7. 10-sec frequency: Calculated as the whole-cycle time during the specified 10 s period8. Voltage waveform peak, Current waveform peak9. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Apparent energy, Reactive energy, Energy cost, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor10. Voltage crest factor, Current crest factor11. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0 th to 50 th orders12. Harmonic voltage-current phase angle: 1 th to 50 th orders13. Total harmonic distortion factor (voltage/ current)14. Inter harmonic (voltage/ current): 0.5 th to 49.5 th orders15. K Factor (multiplication factor)16. (Available in future firmware update) IEC Flicker, Δ V10 FlickerRecordMaximum recording interval: 1 year, Maximum number of recordable events: 9999 × 365 days We are using EMS service. But if you want to use other shipping service such as DHL or Fedex, please contact us before buying.Additional shipping fees may apply depending on the location. We want to make sure you are very satisfied with your purchase. If you experiencing a trouble with you purchase, please contact us within 14 days from the day you received it. Please include the original receipt in your return package or add a note with your eBay username. All items must be returned in original condition. Buyers are responsible for return shipping charges. We'll be happy to assist in any issue you may have. Customer satisfaction is our top priority. We'll respond as soon as we usually send response within 24hours. if you have any questions or need any information, fell free to contact us.