Communication interface: USB
Line voltage: 1.0V~2000V
Maximum Peak Transient Voltage /
Custom Bundle No
Current Measurement Range 0.10A~100A;
MPN 202308311500
Harmonic: Yes, 0 to 50 times
Communication Interface USB
Screenshot capacity: 60
Modified Item No
Voltage Measurement Range /
Brand VTSYIQI
Phase Configuration 3-Phase
Display mode LCD color screen, 640dots×480dots,
Bandwidth /
Transient Record Groups 150 groups
warranty 1 year
Frequency 40Hz~70Hz
Current 040B current clamp 0.10A~100A
Country/Region of Manufacture China
Voltage flicker: Yes
Number of channels 4U/4I.
Expert mode: Yes

Check the listing for details. ETCR5000 Power Quality Analyzer 3 Phase Power Energy Meter + 4pcs Clamp Sensors. Condition: New. Listed at 1980.00 USD. ETCR5000 Power Quality Analyzer 3 Phase Power Energy Meter + 4pcs Clamp Sensors This Power Quality Analyzer comes with 4PCS ETCR040B Clamp Sensors, 0.10A~100A Range. If you needs other sensors , please contact us Introduction: 1. Power Quality Analyzer is a comprehensive test instrument carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, concise man-machine operation. 2. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data. 3. Power quality analyzer adopt DSP + ARM double processor architecture, DSP is use for data collection and the processing of algorithm, the ARM is use for the communication protocol and the man-machine interface processing; Analog signal acquisition is by 2 pieces AD7655 of ADI company. Resolution for AD7655 is 16 bit and it is 4 channel synchronous sampling. 4. The highest sampling rate can reach 1 MSPS, to ensure the accuracy of the channel and the information integrity, and wouldn’t miss any transient changes in the grid, can more accurate to detect the transient waveform rising and dropping drastically, and waveform instantaneous interrupt; DSP working frequency is over 200 MHZ, to be able to timely monitoring of the power grid and dynamically adjust the sampling frequency to realize synchronization of power frequency and sampling frequency; Using a 5.6 -inch LCD color screen display, a resolution of 640 dots x 480 dots, with different display color difference between the parameters of phase, waveform, vector diagram, harmonic ratio, the user can be more efficient and more intuitive understand the state of power grid parameters. 5. Built-in flash memory can store 60 group of screenshots at the same time, 150 groups of capture transient voltage/current waveform figure, and 12800 groups of alarm list. Starting current detection model can continuously capture starting current waveform for 100 s. Built-in 2G memory card to store the trend curve record, simultaneous recording 20 parameters (can choose according to need) collect data for once every five seconds, trend curve records can be stored for 300 days. Function: 1. This instrument is a comprehensive test instrument of multifunctional, intelligent, man-machine operation simple. Comprehensive analysis and diagnosis all the voltage, current, power, electrical energy, harmonic, phase and other electric parameters 2. 4 channel current and 4 channel voltage measurement, simultaneously capturing and recording electric parameters and waveform, to provide with all the power quality information for working. 3. Line voltage:Below 600V Specification: Power supply Rechargeable lithium-ion battery packs 9.6V, backup charger. Battery Level indicator Battery symbol 5 grid Display power, when the battery level is low, automatically shut down after 1 minute indication Working Current about 590mA, continuous working 8hours. Display mode LCD color screen, 640dots × 480dots, 5.6 inches, display field 116mm × 88mm Instrument Size 240mm×170mm×68 mm. CT Size 040Bround jaw current clamp: 35mm×40mm; Number of channels 4 voltages, 4 currents Line Voltage 1.0V~2000V. Phase Voltage 1.0V~1000V. Current 040B current clamp: 0.10A~100A; Frequency 40Hz~70Hz. Electricity Energy Parameter W, VA, Var, PF, DPF, cosφ, tanφ. Energy parameters Wh, Varh, Vah. Harmonic Wave Yes, 0 - 50 times Total harmonic distortion Yes, 0 - 50 times, each phase Expert Mode Yes. Transient Record Groups 150 groups Voltage Flicker Yes Start Current Mode Yes, 100 seconds Three-phases Unbalance Yes Record 300 days (record 20 parameters simultaneously, every 5 seconds record 1 point) Min/Max Recorded Value Yes, the max min value can be measured for a certain time Alarm 40 different types of parameter selection, 12800 group alarm logs Peak Yes. Phasor Diagram Display Automatic Screenshot Capacity 60PCS Menu language English/Chinese. Communication Interface USB. Automatic Shut Down In the alarm/trend graph recording/transient capture mode (waiting or in progress), the instrument does not automatically shut down In other test modes, there is no button operation within 15 minutes, prompting to automatically shut down after 1 minute. Backlight Function Yes, suitable for dark places and nighttime use Instrument Weight Host: 1.6kg (with battery). 040Bcircle current clamp: 190g×4; Test wires and power adapter: 900g; Total weight: about 9.2kg (with package). Voltage Test Wire Length 3M Current Clamp Wire Length 2M Working Temperature -10°C~40°C; below 80%Rh. Storage Temperature -10°C~60°C; below 70%Rh. Input Impedance Test voltage input impedance: 1MΩ Withstand voltage Withstand the sine wave AC voltage of 3700V/50Hz one minute between the instrument line and out shell Insulation Between instrument line and shell ≥10MΩ. Structure Double insulation, with insulation shock-proof sheath. SuitableSafely Standard IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2. Accessories Host: 1PCS; Instrument Bag: 1pcs; Test Cable: 5PCS (yellow, green, red, blue, black); Alligator Clip: 5PCS; Probe: 5PCS; Charger 1PCS; Software CD: 1COPY; 2G Memory Card: 1PCS;Current Clamp ETCR040B 4PCS 2. Instrument Accuracy (excluding the current sensor) The following data are presented in reference conditions and ideal current sensors (completely linear and without phase displacement). Measurement Specification Range Display Resolution Max Error of Reference Range Frequency 40Hz~70Hz 0.01Hz ±(0.03)Hz Phase Voltage True RMS 1.0V~1000V Min resolution0.1V ±(0.5%+5dgt) Line Voltage True RMS 1.0V~2000V Min resolution0.1V ±(0.5%+5dgt) DC Voltage 1.0V~1000V Min resolution0.1V ±(1.0%+5dgt) Current True RMS 10mA~3000A Min resolution0.1mA ±(0.5%+2dgt) Phase Voltage Peak 1.0V~1414V Min resolution0.1V ±(1.0%+5dgt) Line Voltage Peak 1.0V~2828V Min resolution0.1V ±(1.0%+5dgt) Current Peak 10mA~4200A Min resolution0.1mA ±(1.0%+5dgt) Peak Factor 1.00~3.99 0.01 ±(1%+2dgt) 4.00~9.99 0.01 ±(5%+2dgt) Active Power 0.000W~9999.9kW Min resolution0.001W ±(1%+3dgt);Cosφ≥0.8 ±(1.5%+10dgt);0.2≤Cosφ

$990.00
$1,980.00