| Restocking Fee | No |
|---|---|
| Return shipping will be paid by | Buyer |
| All returns accepted | Returns Accepted |
| Item must be returned within | 30 Days |
| Refund will be given as | Money back or replacement (buyer's choice) |
| Frequency Range | Range Auto,Manual |
| Custom Bundle | No |
| Measurement Functions | LCR meter |
| Limitation Measurement | To judge HI, IN, LO and display, with ALARM for HI/LO |
| Product | LCR Meter |
| MPN | 2022 |
| Range | Auto, Manual |
| Modified Item | No |
| California Prop 65 Warning | LCR Meter |
| Brand | VTSYIQI |
| Form Factor | LCR Meter |
| Programmable Time Delay | 0 − 6000mS |
| Output Impedance | LCR Meter |
| Country/Region of Manufacture | China |
Check the listing for details. Digit Multimeter Max Reading 120000 VFD Display High-accuracy 5 1/2 Digit. Condition: New. Listed at 1210.99 USD. Digital True RMS Bench Multimeter High-accuracy 4 4/5 50000 Counts VFD DisplayFeatures■ TH1951 5 1/2 digit display(119,999 counts)■ 12 different measurement capabilities: DCV/ACV, DCI/ACI,Ω2W/Ω4W,Frequency/Period, Diode Test, Continuity, dB/dBm■ High brightness vacuum fluorescent display■ True-rms AC voltage and current measurement, bandwidth up to 100kHz(TH1951)/300kHz(TH1961)■ DCV measurement accuracy up to 0.0035%, resolution up to 0.1uV■ Max. measurement rate: 1000 meas/sec■ Equal accuracy frequency measurement up to 1.1MHz■ Relative mode(REL) to eliminate residual reading■ 2 W, 4W resistance measurement mode selectable■ Built-in mX +b,%, dB, dBm etc. mathematics calculation function■ 512 readings storage and MAX/MIN/AVER/STD statistics■ Up to 30,000 readings storage(without statistics)■ HI/IN/LO comparator function■ USB, BPIB and RS-232 Interfaces provide easy system communication■ Calibration without opening the case■ 10 sets of multimeter setup can be stored and loaded The TH1951/TH1961 5 1/2, 6 1/2 digit multimeter can test voltage/current/resistance fast and accurately. Its outstanding performance,such as max.1,200,000 counts, high reading rate1000 meas/sec as well as DC voltage accuracy of 0.0035% provides an ideal costeffective option for customer.The concise design of front panel of TH1951/TH1961 makes it easier to locate and select the measurement function. High brightness VFD display allows the user to view clearly. Its 12 different measurement functions, including DCV/ACV, DCI/ACI, Ω 2W/Ω 4W, Frequency/Period, Diode Test, Continuity, dB/dBm, cover all basic measurement needs.Many new technologies have been adopted in TH1951/TH1961, such as high speed low noise 26 bits A/D converter which gives the good linear and low noise performances. Fast response servo amplifier, floating power source and low offset buffer amplifier constitute front end of servo so as to remove the traditional attenuation, reduce offset drifting as well as to increase measurement rate. The SMD in the multimeter reduces the system density and volume.TH1951/TH1961 adopts special input overload protect circuit which can stand 1500V voltage between input and ground. When overloaded, it can recover fast so as to ensure the safety and reliability of the equipment.Standard GPIB, USB(or RS-232) interface with universal communication software is used with TH1951/TH1961 for easy TH1951/TH1961 communication, data analysis and statistics as well as construction of an automatic measurement system. The system accepts SCPI(standard commands for programmable instrument) command sets. It is compatible in communication software SpecificationsTest FunctionTest ParameterDCV, ACV, DCI, ACI, Ω2W, Ω4W, FREQ, PERI DIODE, CONTMathematics FunctionmX+b, %, dB, dBm, RELRangeAuto, ManualDisplayVFDTrigger ModeINT/MAN/BUS/EXTProgrammable Time Delay0 − 6000mSReading Storage and Statistics2 to 512 readings can be stored, loaded and countedType of statistics: MAX, MIN, AVER, STDReading HoldTo find out best stable reading for each data block of the given reading number according to the given accuracy.Limitation MeasurementTo judge HI, IN, LO and display, with ALARM for HI/LOSetup Storage10 setup files can be stored and loadedCalibrationRecommend Fluke 5520A with TH1951/TH1961 Accuracy Calibration software( option )Communication InterfaceSCPI command support for GPIB(optional), RS232(optional) and USB(standard) interfaceSpecificationsMeasurement ConditionCalibration interval: one year. Operation Humidity: 18°C−28°C, ≤90%RH; When resistor range is 10M and 100M, ≤70%RH. Warming up time: 30 min. Accuracy is expressed as: +/-(% of reading +% of range). Temperature coefficient: 0°C--18°C & 28°C--40°C, +0.1%×accuracy /°C. Following is the specification at slow mode, others please refer the operation manual .Full Scale Reading Digits and Reading Rate (meas/sec)RateSlowMedFastTH1951 TH1961Full Scale Reading (digits)119,9991,199,999119,99911,999Reading Rate(meas/sec)DC V,DC I4 21657AC V,AC I3 1.5425Ω 2W4 21657Ω 4W3 1.51033DC VRangeMax. readingResolutionAccuracyInput impedanceTH1951100mV119.9991µV0.02+0.008>10GΩ1V1.1999910µV0.01+0.004>10GΩ10V11.9999100µV0.01+0.004>10GΩ100V119.9991mV0.01+0.00410MΩ1000V1010.0010mV0.01+0.00410MΩTH1961100mV119.99990.1µV0.0065+0.0045>10GΩ1V1.1999991µV0.0040+0.0009>10GΩ10V11.9999910µV0.0035+0.0005>10GΩ100V119.9999100µV0.0045+0.000610MΩ1000V1010.0001mV0.0055+0.001510MΩDC IRangeMax. readingResolutionAccuracyBurden voltage/shunt resistorTH195110mA11.99990.1µA0.05+0.008